I suppose data doesn't work? if so, it is not detecting crossed data lines, so not starting dedicated charging. If you don't plan to fix data, you can solder data ports together, or, even better, use kp52 (or higher, in future), and use bq2415x_charger module, in forced "dedicated" mode. You can do it manually, or via bme replacement bits.