    ENNINE | # 1 | 2012-01-03, 02:38 | Report

    I messed up something with rotation screen (want to change orientation threshold like this http://everythingn9.com/adjust-rotat...vity-nokia-n9/ ) and now the rotation is stuck on landscape, and swipe to close is right to left.

    I need original 90-sensord-default.conf


    Thanks.

    Edit | Forward | Quote | Quick Reply | Thanks

     
    zayko | # 2 | 2012-01-03, 03:24 | Report

    Here you go

    ~ # cat /etc/sensorfw/sensord.conf.d/90-sensord-default.conf
    Code:
    device_sys_path = /dev/input/event%1
    device_poll_file_path = /sys/class/input/input%1/poll
    
    # Proximity adaptor
    #proximity_dev_path = /dev/bh1770glc_ps
    proximity_dev_path_rm680 = /dev/bh1770glc_ps
    proximity_dev_path_rm696 = /dev/apds990x0
    
    # Proximity-evdev adaptor for Nokia N900
    proximity-evdev_match_name = gpio-keys
    
    # ALS adaptor
    #als_dev_path = /dev/bh1770glc_als
    als_dev_path_rm680 = /dev/bh1770glc_als
    als_dev_path_rm696 = /dev/apds990x0
    
    # ALS adaptor sysfs for Nokia N900
    als-sysfs_path = /sys/devices/platform/i2c_omap.2/i2c-2/2-0029/device0/illuminance0_input
    
    # Magnetometer drivers
    mag_ak8974_dev_path = /dev/ak89740
    mag_ak8975_dev_path = /dev/ak89750
    
    # Accelerometer coordinate transformation matrix
    # (values separated by commas, concatenate rows from top to bottom)
    acc_trans_matrix = "-1,0,0,0,-1,0,0,0,-1"
    
    # Coefficient for scaling the output of magnetometer sensor
    # Depending on HW/algorithms, the output from driver and in processing
    # may not be milliTeslas. This coefficient can be used to scale them to
    # proper mT values. '300' is correct for AK897X, which use 0.3T as
    # value of LSB. Set to '1' to avoid scaling.
    magnetometer_scale_coefficient = 300
    
    # Orientation parameters
    orientation_threshold_landscape = 25
    orientation_threshold_portrait = 20
    orientation_overflow_min = 800
    orientation_overflow_max = 1250
    orientation_poll_interval = 200
    orientation_buffer_size = 2
    
    # Offset for Screen.TopEdge. If 0, Screen.TopEdge equals side edges from
    # OrientationSensor. Each additional value rotates the top one step to
    # clock-wise direction.
    orientation_offset = 3
    
    # How old samples can we safely ignore for desktop orientation (microsecs)
    # Increase to make more stable, decrease to add sensitivity
    orientation_discard_time = 500000
    
    # How many seconds should we wait without any accelerometer samples
    # to declare that the device must be static?
    # Affects Position.Stable. Note that the property also changes value
    # based on the incoming values, not only this timeout.
    stability_timeout = 60
    
    # The interval used for magnetometer while calibrating (millisecs)
    calibration_rate = 100
    
    # The timeout when calibration stops if calibration level doesn't change (millisecs)
    calibration_timeout = 60000
    
    ### Plugins
    ###
    ### Provide the actual plugin name (libsensor.so --> sensor) for the
    ### plugin dependencies. If a value is not found / set, the key is used
    ### as the value
    
    # Set this to match the device, until automatic detection is enabled
    deviceId = default
    
    [default]
    accelerometeradaptor = accelerometeradaptor
    
    [n900]
    accelerometeradaptor = accelerometeradaptor
    alsadaptor = alsadaptor-sysfs
    proximityadaptor = proximityadaptor-evdev

    Edit | Forward | Quote | Quick Reply | Thanks

     
    ENNINE | # 3 | 2012-01-03, 04:19 | Report

    Thank you man!
    You saved me a flash!

    God bless you!

    Edit | Forward | Quote | Quick Reply | Thanks

     